Advanced Percutaneous Achilles Repair
Aztron Medtech’s TendMIN™ System combines a precision Grasper and Telescoping Needle to enable minimally invasive Achilles tendon repair through a percutaneous approach.
Developed in collaboration with leading orthopedic surgeons and validated in clinical use, TendMIN™ is designed to simplify Achilles repair workflow, minimize incision size, and precision suture placement. Peer-reviewed literature has shown our MIS technique can accelerate time-to-recovery, reduce complications and reduce risk of sural nerve damage for both acute ruptures and posterior bursitis.1-3

The TendMIN™ Technology
TendMIN™ Grasper
Securely navigate under the paratenon
to pass sutures percutaneously
TendMIN™ Telescoping Needle
Easily and quickly pass sutures at optimal tendon
locations under ultrasound guidance
TendMIN™ Differentiators

1. Wang et al. 2012. Ultrasound-Guided Minimally Invasive Surgery for Achilles Tendon Rupture: Preliminary Results
2. Wang et al. 2019. Ultrasound-Guided Minimally Invasive Surgical Resection of Retrocalcaneal Bursitis: A Preliminary Comparison 3With Traditional Open Surgery.
3. Wang et al. 2021. Ultrasonography-Guided Minimally Invasive Surgery for Achilles Sleeve Avulsions
4. Wang et al. 2024. Current treatment concepts for Achilles tendon rupture
*The clinical outcomes presented are based on data from previous studies with an analogous approach and may not represent new or independent clinical trials conducted by Aztron Medtech.
See How TendMIN™ Works
Clinical Case with <1cm Incision
Explore Literature of the TendMIN™ System
White Papers


Percutaneous Achilles Revision Repair Utilizing The Aztron TendMIN™ System
Dr. Thomas P. San Giovanni, MD
This white paper details a case of percutaneous Achilles revision repair on a 50-year-old female with a retracted tendon following a re-rupture. The procedure utilized the Aztron TendMINT™ System for a minimally invasive approach.


MIS Achilles Tendon Repair With The Aztron TendMIN™ System With Anchor Fixation
Dr. Kurt Hofmann, MD
This case details a minimally invasive Achilles repair on an athlete using the Aztron TendMINT™ System with anchors fixation. The ultrasound-guided technique, performed through a small incision, resulted in complete healing and a return to soccer at 6 months.
Peer-review Literature

Ultrasound-Guided Minimally Invasive Surgery for Achilles Tendon Rupture:
Preliminary Results
Chen-Chie Wang, MD, PhD; Pei-Yu Chen, MD; Ting-Ming Wang, MD PhD; Chung-Li Wang, MD, PhD

Current Treatment Concepts for Achilles Tendon Rupture
Chen‐Chie Wang, MD; Pei‐Yu Chen, MD, PhD; Kai‐Chiang Yang, PhD; Chung‐Li Wang, MD; Ing‐Ho Chen, MD

Ultrasonography-Guided Minimally Invasive Surgery for Achilles Sleeve Avulsions
Chi-Yuan Liu, MD; Tsung-Chiao Wu, MD; Kai-Chiang Yang, PhD; Yi-Chen Li, MD; Chen-Chie Wang, MD, PhD

Ultrasound-Guided Minimally Invasive Surgical Resection of Retrocalcaneal
Bursitis: A Preliminary Comparison With Traditional Open Surgery
Chung-Li Wang, MD, PhD; Pei-Yu Chen, MD, PhD; Kai-Chiang Yang, PhD; Hsing-Cheng Wu, MD; Chen-Chie Wang, MD, PhD
Click Our Resources Tab to Read More!
Get in Touch to Learn More!
Address
131 Continental Dr Suite 301
Newark, DE, USA
Contact
+1 (913)-314-1080 (US)
+886 (2)-6605-7607 (Taiwan)




